QUALITY CONTROL

Measured, not assumed

Test plan, instruments and records for each product line.

What we test

Insertion loss, isolation, return loss, polarization dependent loss and wavelength accuracy are measured for every unit. Values are written into the record together with the serial number.

For athermal AWG modules the wavelength drift is verified across the operating temperature range, not at room temperature only.

Test bench

PROCESS

Five checkpoints

01

Incoming inspection

Fiber, chip and package checked before assembly.

02

Assembly

Cleanroom assembly with alignment monitoring.

03

100% test

Sweep test on every unit, data stored by serial number.

04

Aging / temperature

Temperature cycling for modules used outdoors.

05

Outgoing

Report, label and packing list attached to each carton.

INSTRUMENTS

What the data comes from

  • Optical spectrum analyzer
  • Tunable laser + power meter
  • Insertion / return loss test set
  • Polarization controller
  • Temperature chamber
  • End-face inspector
Scroll to Top